Silica Dust Air Sampling – Done Right

Verifying the quality of air your employees are breathing in, is a necessary step for safeguarding their health. Contaminants can come from many different sources. One of the most common contaminants is Crystalline Silica Dust. Excess exposure to silica can lead to incurable chronic conditions like Silicosis. To discover if your employees are effected, an air assessment must be conducted.

Silica dust air sampling has a number of specific requirements that need to be followed to be done correctly. For this, we can follow standards as set by NIOSH. This is not as simple as starting up a 5-gas meter and “sniffing around”. There are a number of considerations to take into account, such as, what population is being sampled, which area(s), and for how long will the assessment take place. Taking extra care to perform silica dust air sampling properly will ensure the assessment results can be trusted and actionable.

Using The Right Equipment

Silica dust is not typical respirable dust. The particles are much smaller and can reach deeper into the lungs (and cause more damage) than regular dust. In fact, silica dust ranges from 0.01 to 100 μm in diameter. Any particles less than 10 μm (or PM10) is hazardous to human health. To accurately measure specifically silica dust exposure, you cannot just use a respirable dust meter. You will instead, need to use a respirable dust cyclone sampler attachment. This cyclone attachment must be connected to the appropriately sized cassette holder, with a filter membrane and support pad contained within. I would recommend using PVC filter membrane instead of MCE as the later is used to microbiological laboratories and clean-room applications.

The next step is to select the appropriate air pump. I prefer GilAir Plus, as it is a reliable device with a wide enough range to accommodate the flow rate required as specified in the NIOSH 7500 standard. Ensure everything is calibrated appropriately before use. Lastly, make sure not to tip the cyclone sampler past horizontal. The grit pot will contain loose particles that can contaminate the filter. If you’re using volunteers to wear personal samplers, you MUST tell them about this requirement.

Using Correct Sampling Methods

To get an appropriate assessment of the exposed population there are a number of standard methods for statistical sampling. A good rule to follow is to sample the square root of the number of individuals in the exposure group, with no less than two individuals’ exposure sampled. Personal samplers should be set-up where the intake is underneath the worker’s chin. This is considered their “breathing zone” and will be representative of the air the worker normally breathes while working. As well, the air pump should be connected to their back belt, with the associated tubing clipped to the wearer’s shirt. This will ensure the sampling materials will not get in the worker’s way while the sampling is taking place.

If you’re conducting area sampling, you must stage the area sampler in an appropriate location. This location must be out of the way so to not interfere with the site operations, but also staged where a representative area air contamination can be assessed. Ensure all devices’ batteries are fully charged and you are well aware of how long the battery will last. Do not forget to mark the time the sampling starts and ends. At the end of this assessment, you will need the time to establish a TWA of exposure.

Getting The Results

Pick a good lab. Not just one that is certified, but one that is easy to work with. Life is too short to deal with people who are nasty, annoying, or difficult. Ensure you have figured out the logistics ahead of time. It is likely, if you have pre-planned this event that the lab you are working with will have sent you filter membranes and cassette holders. Simply follow their instructions in sending them down the sampled filter media. The results should be emailed to you. Make sure to ask questions if the results are not what you expected, even if the lab is certified, mistakes can still happen.

Lastly, compare the results with OSHA’s PEL for silica dust exposure. The limit is 50 μg/m3 per 8-hour TWA. If this limit has been exceeded, resampling is required within 3 months. If the action level is exceeded (action level is 50 μg/m3 per 8-hour TWA), then resampling is required within 6 months. 1910.1053(d)(3)(iii) & (iv).

Final Thoughts

Sampling for silica dust is hard to do right. There are a lot of ways it can be done incorrectly, costing you time and potentially thousands of dollars. Luckily, there are people who specialize in these kind of activities. Some are also easy to work with and come equipped with a never-ending stream of dad-jokes. If you’re looking for support to ensure your workers stay healthy well into their 90’s, please keep us in mind. We’re happy to help get silica dust air sampling done right!