You are currently viewing Respirator Fit Testing: What OSHA Requires

Respirator Fit Testing: What OSHA Requires

I’ve heard “It’s just a dust mask.” to describe respiratory protection more times than I can count. The problem is that the term “dust mask” can mean different things in the field. OSHA’s respiratory protection requirements depend on what type of respirator is being used, why it is being used, and whether its use is required. For employers in construction, the respiratory protection requirements of 29 CFR 1910.134 apply through 29 CFR 1926.103.

When a respirator is required to protect an employee from an occupational respiratory hazard, the employer has more responsibility than simply handing the employee a mask and telling them to wear it. OSHA requires a written respiratory protection program with worksite-specific procedures. They also require appropriate respirator selection, medical evaluation, fit testing when applicable, training, and other program elements.

Respirator Fit Testing Requirements

One of the most commonly misunderstood requirements is fit testing. Under 29 CFR 1910.134(f), employees who are required to use a negative- or positive-pressure tight-fitting facepiece respirator must pass an appropriate qualitative or quantitative fit test before initial use. The employee must also be fit tested whenever a different facepiece is used and at least annually thereafter. An additional fit test is required when there is a change in the employee’s physical condition that could affect the respirator’s fit.

The important phrase here is “tight-fitting facepiece.” Fit testing is intended for respirators that rely on a seal between the facepiece and the wearer’s face. A loose-fitting respirator, such as certain hooded or helmet-style respirators, does not rely on that facial seal and therefore is not subject to the same fit-testing requirement.

That means the common assumption that “every respirator requires an annual fit test” is not quite accurate. The requirement specifically applies to tight-fitting respirators covered by the standard. For those respirators, however, annual fit testing is not optional when their use is required.

Yes, N95 Respirators Can Require Fit Testing

This is where the phrase “it’s just a dust mask” can create problems.

A disposable N95 filtering facepiece respirator is still a respirator. When an N95 is required for employee protection, OSHA’s requirements for tight-fitting respirators can apply. This includes medical evaluation and fit testing. OSHA has specifically addressed filtering facepiece respirators and confirmed that fit testing is required when their use is required under the respiratory protection standard.

Even if the respirator is disposable, lightweight, or commonly referred to as a “dust mask” does not eliminate the requirements. What matters is what the device is and how it is being used.

Fit testing is important because the respirator has to establish an adequate seal with the individual wearer’s face. A respirator that fits one employee properly may not fit another employee properly, even if both employees are using the exact same model.

Medical Evaluation Comes Before Fit Testing

Fit testing is not the first step in the process.

Before an employee is fit tested or required to use a respirator, the employer must ensure that the employee receives a medical evaluation. This is used to determine whether the employee is medically able to use a respirator. The evaluation is performed by a physician or other licensed health care professional and may initially be completed using OSHA’s Respirator Medical Evaluation Questionnaire.

This is another area where terminology matters. OSHA requires the medical evaluation, but that does not mean every employee automatically needs a hands-on medical examination. Depending on the employee’s responses and the determination of the licensed health care professional, additional medical evaluation or examination may be necessary.

There also is not an automatic annual medical evaluation requirement under the respiratory protection standard. OSHA identifies specific circumstances that can trigger the need for reevaluation, including reported signs or symptoms related to the ability to wear a respirator, a determination by the appropriate personnel that reevaluation is necessary, information from the respiratory protection program indicating a need, or workplace changes that substantially increase the physiological burden on the employee.

The medical evaluation and fit test serve different purposes. One determines whether the employee can medically use the respirator; the other determines whether the particular tight-fitting respirator adequately fits that individual.

Required Use vs. Voluntary Use

Another important distinction is whether the employer requires the employee to use the respirator or whether the employee is using it voluntarily.

When respirators are necessary to protect employees or are required by the employer, the full respiratory protection program requirements apply. That includes the applicable requirements for respirator selection, medical evaluation, fit testing, training, maintenance, and program administration.

Voluntary use is treated differently. OSHA has specific provisions for employees who choose to wear respirators when their use is not required. For voluntary use of filtering facepiece respirators, the requirements are more limited, although the employer must still provide the information in Appendix D and ensure that the voluntary use itself does not create a hazard.

This distinction is important because an employee choosing to wear an N95 for personal comfort or preference is not automatically in the same situation as an employer requiring that employee to wear an N95 because of an occupational exposure.

Fit Testing Is More Than Paperwork

It can be tempting to view annual fit testing as another compliance box to check. In reality, it addresses a basic question: does this respirator actually fit this employee?

A proper fit test evaluates the relationship between the specific respirator and the individual wearer. OSHA’s mandatory fit-testing procedures address factors such as respirator size, positioning, and the adequacy of the face seal.

There are also practical considerations that can affect the seal. Facial hair that comes between the sealing surface and the skin, for example, can interfere with the respirator’s ability to form the required seal. Changes in facial structure, significant dental work, or other physical changes can also affect fit and may require another fit test.

The goal is not simply to have a signed fit-test form in a file. The goal is to make sure the respiratory protection selected by the employer can actually provide the intended protection when the employee performs the work.

Before You Call It “Just a Dust Mask”

Respiratory protection can look deceptively simple. A disposable filtering facepiece may look like a basic piece of PPE. But, things change once its use becomes necessary or required for protection against an occupational hazard. In that case, OSHA’s respiratory protection requirements can become considerably more involved.

Before requiring employees to wear a respirator, employers should consider the following. What type of respirator is being used. What hazard it is intended to control. Whether its use is required, whether it is tight-fitting, and what OSHA requirements apply. That determination should then be reflected in the employer’s respiratory protection program and work practices.

Sometimes “it’s just a dust mask” isn’t nearly as simple as it sounds.

References